I like to talk about unscheduled events on the PT6A engine from time to time. Unscheduled events are the incidents that none of us want or need, but they happen despite our best efforts. There is a pretty extensive list of events that Pratt & Whitney Canada describes as unscheduled events in the maintenance manual. They cover everything from a prop strike to immersion in water. I will try and discuss these events; however, the list is too long to discuss in one article. In this article, let’s look at some exceedances; specifically, we will look at over-torque and over-temperature.
When either a temperature or torque event occurs, information will be critical. Knowing the answer to the following questions is extremely important: How far above redline? How long did it stay above redline? This information helps the engine shop determine the work scope required to return the engine to service. This is where the MVP-50T or any engine monitoring system comes in handy. Recorded data can be downloaded and provide accurate readings on exceedance and duration. When something outside the ordinary happens, the pilot can be busy, and the most important thing is to get the airplane safely on the ground. That is why engine monitoring systems are a benefit to an operation.
When one of these unscheduled events occurs, you may be asked to complete a service information letter Gen-135. This is a form describing the circumstances of what happened. If the engine is still under warranty, there may also be a requirement for a second form to be completed by Pratt & Whitney Canada. Ask for help if needed. We always want to ensure that you don’t inadvertently cause yourself struggles and pain by not crossing all the t’s. You can also visit about what needs to be done with your Pratt & Whitney Canada field service rep or C-First.
Now, what is the first step if an over-temp event has occurred or is suspected? The first thing we must do is make sure the indicating system is functioning correctly. Make sure what the pilot witnessed was being accurately reflected in the cockpit. Next, we must discuss the over-temp event. Key components of this event are peak temp reached and duration. The maintenance manual has a chart where you can line up the temp and time, and the chart will provide the maintenance requirements. There is a limit where no action is required if the event occurred in the range. The next level is to determine and correct the cause of the over-temperature. After an over-temp, a visual inspection of the engine may also be a maintenance requirement. As temperature and duration go up, so does the level of maintenance. If it cannot be determined how long the event lasted or what the peak temperature reached was, then one must assume the worst case. Engine removal and engine shop visit are required for all Area C category events. You will need to indicate “Unknown Temperature” when sending the engine in for an inspection when the temperature cannot be determined. This is the signal to the engine shop on how to proceed. The inspection process can include destructive testing of at least two compressor turbine blades, followed by other inspection requirements in the PT6 manual. These actions are for over temp events that are not at the start. If you have an exceedance of temperature on startup, there is a separate chart to determine what steps must be taken.
The maintenance manual also discusses inadvertent cut-off and relights of the engine during taxi. This is an event of its own and should be handled as stated in the maintenance manual. We have seen issues directly linked to inadvertent cut-off and relight, including failure of the compressor turbine blades. It is extremely important to follow the inspection criteria when you have such an event.
Shifting the focus to over-torque, like the over-temp event, there is a chart with the duration on one side and maximum torque reached on the other. Maintenance requirements are from no maintenance action to return the engine to the shop. If you fall between those categories, there are actions to monitor in your engine. First, we want to verify the indicating system is accurate. Next, look at the oil system. We are looking for metal and debris in the oil. Rotate the propeller, listening for unusual noise. Pull the chip detector(s), oil strainers, and the oil filter and look for debris. If everything looks and sounds normal, perform a ground run per the maintenance manual. Ensure that nothing has changed in propeller operation, such as acceleration on start or abrupt deceleration on shutdown. Run the engine to a specified power setting as set out in the manual. Once the engine run is complete, pull filters, strainers, and detectors again, looking for debris. Then follow up this same round of checks in the prescribed time in the future. For instance, in one manual, we run the engine at 80% for 10 minutes and make our checks. Perform the checks again in one week/25 hours minimum.
Suppose you have an over-torque that is at the top of the chart, which requires removal for inspection and servicing. You can be thankful that the PT6A has a modular design. You might be able to only remove the power section on the PT6A and send it in for repair rather than pulling the complete engine.
I always tell everyone to listen to their engine and watch for changes. The PT6A is a solid engine that will let you know when something is wrong. If you see something in your normal operation of the engine that strikes you as odd or different, ask about it. Talk to your mechanic about what is different. It may be nothing or an indication that something more dramatic could be coming. Finally, if you have an exceedance, don’t ignore it. Let’s all hope that we can avoid anything unscheduled.
Please reach out to me at robertc@covingtonaircraft.com if you have any questions, and I’ll be glad to assist.